Hey @Nils!
Thanks you for the log. The real problem seems to be that Redpanda never fully starts. Because of that, your OPC-UA read flow can never be applied. It's not an OPC-UA problem yet, Redpanda seems to block everything.
You could try these steps real quick:
- Do a full restart of the umh-core container, not just a redeploy in the UI. This is the most common fix when Redpanda gets stuck like this.
- Check how much CPU and RAM your container has. Redpanda needs a full CPU core and some extra memory. Give it at least 2 CPUs and 4GB RAM if you can.
- If it's still stuck, open the Redpanda component itself and check its logs. Does it ever turn green, or does it stay grey/starting forever?
- If Redpanda does turn green but the bridge still won't apply, check that your OPC-UA server is actually reachable from inside the container. "localhost" won't work if the test server runs on your host machine. Try host.docker.internal or your machine's real IP instead.
If restarting doesn't help, please send us whether you run Docker or bare metal, which OS you are running, how much CPU/RAM you gave it. The logs from right when it starts (anything mentioning redpanda) would be helpful aswell.
Then we can tell quickly if it's the Redpanda issue or something else.